Chloride Titanium Dioxide for Coatings: Hiding, Tinting Strength and Gloss

White coated panels, an opacity drawdown card and a gloss meter in a coating laboratory
AI-generated application illustration; not a photograph of the reported test.
Quick answer: Choose chloride titanium dioxide for coatings by checking opacity, tinting strength, colour and gloss together in your actual binder system. ICC CR-85 is a chloride-process rutile candidate for this balance. Begin with equal pigment loading, then optimise only after the candidate meets the coating specification.

Buying a coating pigment by powder whiteness or manufacturing route alone leaves important questions unanswered. Will the paint hide the substrate at the intended film build? Can the tinting system reach the approved colour? Does the applied film retain the specified gloss? These are separate purchasing requirements, even when they are influenced by the same pigment.

This guide explains how to evaluate CR-85 chloride-process rutile titanium dioxide, interpret its application evidence and organise a useful supplier trial. It is intended for coating formulators and purchasing teams comparing a candidate with an incumbent grade.

What does chloride-process titanium dioxide tell you?

Chloride processing identifies the pigment manufacturing route. It does not, by itself, specify the finish of your paint. The commercial grade, surface treatment and compatibility with the formulation still need evaluation. A request for “chloride TiO₂” should therefore include the application, binder, required opacity and target finish.

CR-85 has alumina, zirconia and organic surface treatment. ICC lists coating applications including solvent-based coatings, can coatings, marine coatings and inks. An application listing is a starting point for screening; a laboratory acrylic result is not a qualification for every coating within those categories.

Keep three document types separate when reviewing a supplier: the TDS describes the grade and specification, the lot inspection document relates to supplied material, and an application report describes particular samples in a particular formulation. They answer different questions.

Hiding, tinting strength and gloss: what should you measure?

Use one acceptance sheet for all four properties. A favourable hiding result does not cancel a failed colour tolerance. Equally, a high gloss reading is not an advantage when the product specification calls for a different finish. Agree the acceptable ranges before comparing samples.

Contrast ratio compares the reflectance of a coating over black and white areas. Record the film preparation alongside the number. Two readings obtained at different thicknesses do not establish which pigment is more efficient. For shade, retain the L*, a* and b* coordinates rather than reducing the entire decision to a single whiteness index.

Property Useful question Comparison control
Hiding or opacity Does the dried coating mask a contrasting substrate at the required thickness? Same opacity card, loading, dry-film thickness and drying conditions.
Tinting strength How does the white pigment perform against the chosen reference in a tinted paint? Same colourant batch, ratio, binder and reference calculation.
Gloss Does the coating meet the specified surface finish? Same gloss angle, substrate, application method and cure.
Colour and undertone Does the coating match the approved white or tinted shade? Same instrument settings, backing, film preparation and conditioning.

What the CR-85 acrylic coating report actually shows

The CR-85 Acrylic Coating Application Performance Report covers six samples tested on 6 January 2024, published as version 1 in 2025. In white paint, CR-85 recorded 93.2% contrast ratio and 20° gloss of 69. A separate grey-paint evaluation reported 100.0% relative tinting strength.

White paint used a thermoplastic acrylic resin solution with 27% solids at 16% pigment volume concentration. Grey paint used a 33%-solids solution at 15% pigment volume concentration. Preparation included glass-bead grinding below 10 μm, a 100 μm wet-film applicator and air drying. Here, PVC means pigment volume concentration.

The grey-paint b* value was −2.07, less blue than the five benchmarks in that test. Position CR-85 around its combined hiding, tinting and gloss performance; verify cool-white or strongly blue undertone targets separately. These historical data establish neither a universal ranking nor a guaranteed dosage reduction.

A practical CR-85 qualification sequence

The purpose of this sequence is traceability. If a trial improves after an additive change, the purchasing decision concerns that complete formulation. Keeping the initial substitution and the optimised version separate makes the result easier to reproduce and explain.

  1. Define the product to be matched. Record the binder, intended substrate, application method and approved coating standard. Include white paint and at least one commercially important tinted shade if the pigment will serve a tinting range.
  2. Prepare an incumbent control. Use a retained pigment and known formulation. Make the control during the same trial as the candidate so that changes in preparation or drying are less likely to be mistaken for grade effects.
  3. Run the initial replacement at equal loading. Hold the resin, additives, pigment volume concentration and dispersion procedure constant. Record fineness, viscosity and preparation time as observations, without assigning a saving before it has been measured.
  4. Apply reproducible films. Use the same substrate and applicator. Measure or otherwise control the relevant film thickness, label the panels and allow the same conditioning period before reading colour, hiding and gloss.
  5. Optimise a promising candidate separately. If dispersant, resin or process settings change, assign a new formula code. Recheck the whole acceptance sheet instead of carrying over the original optical results.
  6. Confirm production relevance. Repeat the comparison, then evaluate the candidate using the intended production equipment and application process. Retain approved panels and the final formulation as the purchasing reference.

How to diagnose a disappointing trial

Avoid changing several ingredients at once when diagnosing a failed screen. A short series with one controlled change is usually more informative than a single extensively modified formula whose result cannot be attributed to a specific decision.

For coatings with additional durability, adhesion or chemical-resistance requirements, include the relevant end-use qualification. An optical application report does not replace those tests.

Observation Next check
Hiding is below target Confirm film thickness and pigment loading first; then review dispersion and the formulation balance.
Gloss drops while hiding is acceptable Check surface finish, application, cure and dispersion before attributing the change to pigment chemistry.
Tinted colour moves away from the standard Check the colourant ratio and reference; compare undertone separately from relative strength.
Viscosity changes after substitution Review wetting and additive compatibility; record any adjustment and retest the coating.
A laboratory pass does not repeat in production Compare raw-material lots, dispersion conditions, scale, film application and conditioning records.

Compare coating grades by the purchasing objective

Start with CR-85 when the brief prioritises chloride-process TiO₂ and a balance of hiding, tinting and gloss. For a project centred on formulation cost, include R-F9300 in the discussion. For a water-based formulation requiring a specific dispersion and hiding evaluation, consider R-F9490.

These positions help narrow the trial, but do not create a league table across different reports. Compare shortlisted grades in the same customer formulation and evaluate the cost of the approved coating, including any necessary additive or process changes.

Frequently asked questions

Is chloride titanium dioxide always better than sulphate TiO₂ for coatings?

A manufacturing route does not decide every application result. Specify the route if it is part of the purchasing requirement, then qualify the particular grade against the coating’s optical, processing and end-use limits.

Can a strong tinting result justify using less pigment?

It can justify testing a lower loading. It does not establish the replacement ratio. Prepare the reduced-loading formula and confirm hiding, colour, gloss and the remaining product requirements before calculating a saving.

Should I compare 20° and 60° gloss values directly?

No. Record the measurement angle and use the angle required by the coating specification. Numbers measured at different angles should not be treated as interchangeable.

What should accompany a CR-85 sample request?

Provide the resin, pigment loading, current grade, dispersion equipment, application method and target shade. A reference coating panel or a defined colour standard can make the trial brief more precise.

Discuss a CR-85 coating trial

Send ICC your resin system, application method, incumbent TiO₂, pigment loading, target film thickness and acceptance limits. Request the current CR-85 TDS and a sample for a controlled comparison. Include the required shade and finish so the discussion addresses the coating you need to sell.

Compare ICC titanium dioxide grades for coatings · Request samples and a quotation

Titanium Materials Solutions for Industrial Applications

Explore ICC titanium dioxide, infrared-reflective TiO₂, high-purity titanium materials and titanium-based lithium adsorbents, supported by application testing and technical service.
Scroll to Top